Development of a calibration-assistance optimization framework for 3D ELCOM-CAEDYM water-quality modeling
Hyo-Yeong Jo1,2, Han-Pil Rhee1,2  , Jangwon Son2, Seungjae Lee3, Jin-Young Jun2, and Soon-Jin Hwang1 
1Department of Environmental and Health Sciences, Konkuk University, Seoul 05029, Republic of Korea
2ET Waters Co., Ltd., Seoul 08376, Republic of Korea
3Korea Water Resources Corporation (K-water), Daejeon 34350, Republic of Korea
Corresponding Author: Han-Pil Rhee ,Tel: +82-2-455-3931, Fax: +82-2-455-3934, Email: hprhee@etwaters.co.kr
Soon-Jin Hwang ,Tel: +82-2-450-3748, Fax: +82-2-455-3934, Email: sjhwang@konkuk.ac.kr
Received: February 5, 2026;  Accepted: May 20, 2026.
Share :  
ABSTRACT
Three-dimensional (3D) hydrodynamic and water-quality models can represent spatial heterogeneity in stratified reservoirs, but their routine operational application is limited because calibration requires repeated model runs. To address this limitation, this study proposes a calibration-assistance optimization framework for 3D water-quality models that reduces the number of runs needed to reach an acceptable parameter set. The framework was implemented using the Estuary, Lake and Coastal Ocean Model (ELCOM) coupled with the Computational Aquatic Ecosystem Dynamics Model (CAEDYM). Unlike conventional approaches that rely on many separate runs during calibration, the proposed method compares simulated and observed values from each run across multiple stations and sampling dates and combines those differences to guide the next parameter update. This allows each run to provide multiple pieces of calibration information while reducing repeated executions. Chlorophyll-a (Chl-a) was used as the primary calibration target for evaluating the proposed framework. Application to Daecheong Dam and Namgang Dam showed convergence within 3–7 optimization iterations (i.e., 3–7 model runs), with total turnaround times of approximately 17–24 h. These results indicate that the proposed workflow can support reproducible calibration adjustment for computationally expensive 3D models.
Keywords: Calibration-assistance optimization | Chlorophyll-a | ELCOM-CAEDYM | Parameter calibration | Sensitivity analysis | Stratified reservoir
TOOLS
PDF Links  PDF Links
Full text via DOI  Full text via DOI
Download Citation  Download Citation
Share:      
METRICS
0
Crossref
0
Scopus
299
View
14
Download
Editorial Office
464 Cheongpa-ro, #726, Jung-gu, Seoul 04510, Republic of Korea
FAX : +82-2-383-9654   E-mail : eer@kosenv.or.kr

Copyright© Korean Society of Environmental Engineers.        Developed in M2PI
About |  Browse Articles |  Current Issue |  For Authors and Reviewers